What Causes Maintenance Problems with Air Conditioners on Iran CNG City Buses?
DATE: Oct 23rd, 2025
Read:
Share:
What Causes Maintenance Problems with Iran CNG City bus Bus Air Conditioner? The stable operation of Iran CNG City bus Bus Air Conditioner directly impacts passenger comfort and vehicle safety. However, a malfunction in the Bus Air Conditioner not only diminishes the ride experience but can also pose safety risks due to high temperatures or equipment overload. So, what causes bus air conditioning maintenance problems? This article will systematically analyze the root causes of these problems from three perspectives: the circuit system, the refrigeration cycle, and mechanical components, drawing on real-world repair cases. Circuit System Failure: The "Invisible Killer" of Air Conditioner Short Circuits Air conditioner short circuits are a common cause of sudden air conditioner failures on Iran CNG city buses. According to a maintenance log, a vehicle with a sudden air conditioner shutdown was found to have insulation damage in the input wiring due to long-term wear, ultimately causing a short circuit. This problem is often accompanied by a blown fuse or tripped circuit breaker. Maintenance personnel should focus on measuring the resistance of the air conditioner input wiring and using a multimeter to detect a direct short circuit. They should also check the insulation of the outdoor unit motor and compressor windings to determine if moisture or aging have caused a ground short circuit. Furthermore, minor issues like capacitor expansion on circuit boards and burnt-out relay contacts can easily go unnoticed For example, a bus air conditioner experienced motor failure due to a decrease in the compressor's starting capacitor capacity. While these issues don't directly cause a short circuit, they can increase circuit load and ultimately lead to systemic failure. Therefore, regularly using an insulation resistance tester to check circuit conditions is key to preventing short circuit risks. Refrigeration Cycle Abnormalities: The "Butterfly Effect" of Refrigerant and Piping Refrigerant leakage is one of the main causes of reduced cooling efficiency in Iran CNG City bus Bus Air Conditioner. During a maintenance operation, a technician detected abnormally low refrigerant pressure using a pressure gauge and, using an electronic leak detector, confirmed tiny cracks in the evaporator's solder joints. These leaks may initially manifest as insufficient cooling, but prolonged operation can cause the compressor to frequently shut down due to low-pressure protection, ultimately leading to mechanical damage. Pipeline blockages are also a refrigeration cycle issue. For example, impurity buildup can clog the capillary tubes of a filter drier, or dust can build up on the evaporator's fins, impacting heat exchange efficiency. A long-distance bus company experienced frequent air conditioning system shutdowns due to high-pressure protection due to failure to clean the air conditioning filter promptly. During maintenance, a large amount of willow catkins and insect debris was found clinging to the condenser surface. After cleaning, the system resumed normal operation. Therefore, quarterly pressure testing and cleaning of the pipes is recommended to prevent blockage risks. Mechanical Component Wear: The "Fatigue Battle" Between the Compressor and the Fan As the core power source of the air conditioning system, compressor wear is a critical issue. During a maintenance operation, a bus's air conditioning system was found to be operating abnormally due to compressor bearing wear. Increased vibrations led to internal component fractures. Inspections revealed that the compressor lubricant had oxidized due to prolonged high-temperature exposure, losing its lubricating properties and exacerbating mechanical wear. Such problems can be prevented by regularly changing the lubricant and checking bearing clearances. Aging fan motors and belts also affect system stability. For example, a loose fan belt on one vehicle caused a drop in speed, reducing condenser heat dissipation efficiency and ultimately triggering compressor overload protection. During maintenance, belt tension adjustment and replacement of the aged motor restored the system to normal operation. It is worth noting that the wear of mechanical parts is often gradual, and during daily inspections, special attention should be paid to early warning signals such as abnormal noise, vibration, and abnormal temperature.